Sensors

LD360s™ Load Cell

Designed for Sanitary Wash-Down Environments

Simple, self-contained design virtually eliminates bacteria hiding places and withstands rigorous CIP cleaning practices.

  • Standard load ranges are from 1,000 lb (453 kg) to 25,000 lb (11340 kg) per support
  • Easy to install with a single footprint and height dimension
  • Minimal deflection reduces plumbing effects for better system accuracy
  • Optional hardware with built-in leveling features eliminates the need for shimming
  • NEMA – 6P water resistant


Specifications

  • Average Accuracy: 0.08%
  • Excitation Voltage: 10 to 30 VDC
  • Excitation Current: 3 mA
  • Defection: Maximum, depending on capacity 0.012 in.
  • Functional Integrity: 2x rated load in compression
  • Structural Integrity: 4x rated load in compression
  • Operating Temperature: -30° to 150° F (-34° to 66° C) – Standard
  • Operating Temperature: -30° to 200° F (-34° to 93° C) – High Temperature
  • Dimensions:
    Installed Height: 2.7 in. (69 mm) for up to 10K; 3.3 in. (84 mm)  for 15 to 25k models
    Footprint: 6 x 3.5 in. (152 x 89 mm) (Length x Width)